Intel® Server Chassis SC5400

Maximum Reliability, Scalability, and Manageability in a Highly Versatile Intel® Server Chassis
The Intel® Server Chassis SC5400 offers an ideal solution for a variety of business environments. With great reliability, wide-ranging scalability, strong manageability, the SC5400 is a solid, cost-effective solution for a range of environments, from small businesses to database servers. The SC5400 chassis family supports SAS, SATA and SCSI drives for configuration and application flexibility. Applications needing maximum reliability, serviceability and uptime can benefit from the SC5400LXI SKU, which integrates fully redundant hot-swap power supplies and fans, and support for 6-drive hot-swap SAS/SATA drives.

Product Specifications
Form factor
Pedestal or 5U rack (requires rack conversion kit ARIGRACK)

Drive bays
Base
One tool-less fixed drive bay for up to six fixed drives
Optional hot-swap / tool-less drive bays available:
6-drive SAS/SATA
6-drive SCSI
BRP, LX
One tool-less fixed drive bay for up to six fixed drives
Optional hot-swap / tool-less drive bays available:
6-drive SAS/SATA, 4-drive SAS/SATA
6-drive SCSI, 4-drive SCSI
Optional 4-drive tool-less fixed drive bay
LXI
Includes: One hot-swap 6-drive SAS/SATA drive bay (product code AXX6DRV3G). Optional support for 4-drive SAS/SATA drive bay (AXX4DRV3G or AXX4DRV3GEXP).

Hot-swap disk drive bay: order code
Base
Up to six hot-swap drive bays via the following hot-swap disk drive bay upgrade kits:
6-drive SCSI – AXX6SCSIDB
6-drive SAS/SATA – AXX6DRV3G
6-drive SAS/SATA Expander – AXX6DRV3GEXP
BRP, LX
Up to ten hot-swap drive bays are possible with the combinationof the following drive bay upgrade kits:
6-drive SCSI – AXX6SCSIDB
6-drive SAS/SATA – AXX6DRV3G
6-drive SAS/SATA Expander – AXX6DRV3GEXP
4-drive SCSI – AXX4SCSIDB
4-drive SAS/SATA – AXX4DRV3G
4-drive SAS/SATA Expander – AXX4DRV3GEXP
LXI
Up to ten hot-swap drives are possible with the combination of the following, optional, drive bay upgrade kits:
4-drive SAS/SATA – AXX4DRV3G
4-drive SAS/SATA Expander – AXX4DRV3GEXP

Power supply
Base
670-watt PFC
BRP, LX, LXI
830-watt, dual-line cord, 1+1 PFC
Hot-swap, redundant power capable
Base
Via upgrade kit
BRP, LX
Fully redundant configuration (requires optional second power module FXX830WPSU)
LXI
Fully redundant configuration (ships with two power supply modules FXX830WPSU)

Hot-swap, redundant fans
Base
2 non-redundant fans. Hot-swap redundant fans not available.
BRP
2 non-redundant fans. Hot-swap, redundant fans available via upgrade kit (ARIG2HSFANKIT).
LX, LXI
Fully redundant configuration (ships with 4 hot-swap fans)

Comments